FTE series is small, lightweight and highly accurate gas meter to enable large volume measurement of gas.
Features
Wide measuring range and high accuracy
It has a wide flow rate measuring range and has high measuring accuracy far precise than the calibration tolerance specified in the Measurement Law of Japan.
Highly accurate calculation
Highly accurate calculation can be made by accurate pressure sensor, temperature sensor and microcomputer.
Possible to read both temperature and pressure
In addition to the temperature compensation calculated value, it displays the integrated value of non-compensation, temperature compensation, pressure compensation, and temperature and pressure value.
Battery driven type
It can be used without changing built-in battery for seven years, and the power supply work is not required.
Standard specification
Measuring unit
Applicable Fluid | City Gas, Natural Gas, Air, LPG Gas, etc. | ||||
Accuracy | Conforming to Calibration tolerance | ||||
Flow Rate Range | 32 – 4000 m3/h (depends on connection size) | ||||
Fluid Temperature
|
-10- 40 ℃ | ||||
Pressure Loss |
Model number 0650; at max. flow rate 1.96 kpa (200mmAq)
Model number 10000 over; at max. flow rate 0.98kpa(100mmAq) |
||||
Max. Working press. | Max. O49MPa (10kgf/cm2) | Max O97MPa (9.9kgf/cm2) | |||
Temperature Pressure | Max. 097 Mpa (9.9 kgf/cm2) | ||||
Connection Size | 100mm (4B) – 300mm (12B) | ||||
Flange Rating | JIS 10K, RF | ||||
Material | Body | FCD450 | |||
Rotor | ALUMINUM | ||||
Others | SUS304 and others | ||||
Inflow Direction | Left to right (Standard) | ||||
Paint color | Munsel1 1.4pb 3.1/1.2 |
Display unit
Display
|
Integrated Value | 7-digits (non-compensation)
|
|
Segmentalised flow rate | Display ten aliquot of the least
Significant digit of the integrated value
|
||
Error Outbreak | Display (E) to the most significant digit at the time of error outbreak | ||
Function | Coefficient compensation | Convert a rotor turn into a unit pulse
|
|
Instrumental error compensation | Linearization of instrument error
|
||
Discrimination of direct-flow and back-flow | Add and subtract the direct-flow and back-flow and display the integrated value
|
||
Over metering | Overshoot compensation at the time of
sudden valve shutoff |
||
Output Pulse | Output signal | Open drain | |
Power source | Max. 6V, DC 500 mA | ||
Pulse width | 0.25 sec.
|
||
Lithium battery | Battery lifetime 7 years | ||
Ambient Temperature | -10 – 40C |